Main Features
●Standalone input power: 2~60kW, 3U/6kW high power density
●Voltage range: 0~150V/0~600V/0~1600V/0~2400V
●Current range: up to 2500A
●CV, CC, CP, CR three ranges, wide measurement range
●Current measurement accuracy: 0.04%+0.04% F.S.
●Voltage measurement accuracy: 0.015%+0.015% F.S.
●1.6 times power loading capacity in a short time<3s
●Adjustable CV loop speed, matching different power supplies
●Voltage/current sampling rate: up to 500kHz
●Supporting parallel control, and realizing power expansion via master+master, master+slave
●Supporting SEQ test, discharge test, charge test, OCP/OPP test and short-circuit simulation
●Operation modes: CC, CV, CP, CR, CV+CC, CR+CC, CV+CR, CP+CC
●Supporting current monitoring output, external programming input, external trigger input, and 10kHz sine wave programming input
●30kHz high-speed dynamic mode, dynamic frequency sweep function
●Time measurement, rise/fall time measurement accuracy: 10μs
●Arbitrary waveform load test (Optional), sine wave up to 20kHz, supporting USB flash drive import
●Equivalent series resistance( ESR) test (Optional)
●Soft on/off function, current oscillation protection function
●Multiple protection: OCP, OVP, OPP, OTP and reverse connection detection
●Supporting 100 groups of parameters to be saved and fast recalled
●LAN/RS232/CAN as standard interface, GPIB as optional interface
●Supporting MPPT maximum power point tracking function
Application Fields
●New energy fields, such as fuel cell stacks and engines, lithium battery packs, supercapacitors, photovoltaic modules, etc.
●High-power DC power supply, such as industrial power supply, server power supply, communication power supply, etc.
●Power electronic products, such as UPS power supply, DC-DC converter, on-board charger, etc.
●Power supply, such as generator set, energy storage system, DC charging pile, etc.
●DC high-power devices, such as contactors/relays, automotive high-voltage accessories, etc.
Functions & Advantages
3U/6kW Ultra-High Power Density
The N69200 is designed with an exceptionally high power density. A 19-inch 3U chassis can deliver up to 6 kW, representing only half the volume and weight of traditional electronic loads. Compared with conventional loads of the same power level, the N69200 offers a significantly smaller footprint and lighter overall mass.

Parallel Connection for Power Expansion
The N69200 supports parallel operation. When higher load power is required, units with the same voltage rating can be connected in parallel (master + master or master + slave) to achieve the desired current and power capacity. During use, operators only need to configure the current on the master unit; the slave unit automatically allocates its current output, simplifying overall system setup and operation.

Multiple Operating Modes for Diverse Test Scenarios
The N69200 supports four standard operating modes: CC, CV, CP, and CR. To address variations in load characteristics during real-world testing, four combined modes-CV+CC, CR+CC, CV+CR, and CP+CC-are also provided.
• CR+CC is ideal for power supply startup testing to prevent overcurrent protection triggering at power-on.
• CV+CR can replace the traditional Von point configuration.
• CV+CC can simulate the transition process between operating states during battery charging.
Users may select the appropriate mode according to their specific test requirements.

High-Speed Dynamic Mode with Frequency Sweep
The N69200 provides a high-speed dynamic mode for evaluating the dynamic characteristics of DC power supplies by simulating real-world load transients. It includes programmable dynamic operations up to 30 kHz and supports CCD (constant current dynamic), CVD (constant voltage dynamic), CRD (constant resistance dynamic), and CPD (constant power dynamic).
The programmable dynamic load function allows configuration of high/low ranges, rise/fall slew rates, pulse widths, and operating modes. In dynamic frequency sweep mode, voltage and current sampling rates reach 500 kHz, enabling linear load-current frequency sweeping up to 30 kHz. This mode measures Vpk+, Vpk–, and their corresponding frequencies during frequency-dependent load variations of the DUT.

Charge/Discharge Test with Built-In Battery Test Mode
Users can configure diverse test conditions directly from the front panel. For example, when the battery voltage drops below the initial value, the internal counter begins operating and continues until the battery voltage reaches the defined cut-off threshold.

OCP (Overcurrent Protection) Test
During an OCP test, the N69200 operates in CC mode and monitors whether the DUT voltage falls below the cut-off voltage. If the voltage is below the threshold, the N69200 records the real-time loading current as the test result and then disables the input to terminate the test. If the DUT voltage remains above the threshold, the N69200 increases the load current until the voltage drops below the cut-off point or until the maximum loading current is reached.

Equivalent Series Resistance (ESR) Test (Optional)
ESR is a critical parameter for batteries and supercapacitors. The N69200 series provides a professional ESR measurement function that supports multiple test standards. It delivers accurate measurements with excellent repeatability and stability.